Gravimetric methods for the determination of fat contents after acid hydrol
ysis yield reliable results, since the portion bound to proteins and starch
is also included. The methods in current use are rather time and solvent c
onsuming. For this reason, a simplified procedure was developed. The food s
ample is heated with hydrochloric acid and toluene for both hydrolysing the
matrix and extracting the fat in the same step. An aliquot portion of the
organic phase is evaporated and the fat residue is weighed. The results obt
ained for different kinds of foodstuffs are virtually the same as those fou
nd by using official methods. In comparison, the micro method described has
several advantages: Only 5 ml of organic solvent are required instead of 2
00 ml. The results are obtained within 1.5-2.5 h instead of 8 h. The time i
nvolved in manual work is only 10 min instead of 1 h. The fat is isolated u
nder mild conditions and can be analysed further with other methods. When c
ompared to instrumental procedures for determining the fat content, the mic
ro method needs only simple equipment which is anyway in current use in lab
oratories. It is not liable to errors and interferences, can be applied to
virtually all kinds of food and needs only small laboratory space.