The MR head is being studied for use in helical-scan guardband-less tape sy
stems, These systems need a read head with a wider track width than track p
itch, so the track profile of the head is important. We analyzed the track
profile of MR heads, and found that fluctuations in the reading signal are
not an issue. We then mounted the head on a tape-streamer drive and measure
d the SNR, We found that the MR head provided an SNR which makes it possibl
e to double the areal density with a margin more than 6 dB over that of an
inductive head.