Calibration of fly height measured by scattered total internal reflection

Citation
Cw. Strunk et al., Calibration of fly height measured by scattered total internal reflection, IEEE MAGNET, 36(5), 2000, pp. 2727-2729
Citations number
13
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Journal title
IEEE TRANSACTIONS ON MAGNETICS
ISSN journal
00189464 → ACNP
Volume
36
Issue
5
Year of publication
2000
Part
1
Pages
2727 - 2729
Database
ISI
SICI code
0018-9464(200009)36:5<2727:COFHMB>2.0.ZU;2-R
Abstract
Fly height was measured using Scattered Total Internal Reflection (SCATIR), A calibration method for this technique was developed, and the results wer e compared to those from a Phase Metrics Dynamic Fly Height Tester (DFHT) I I. Measurements from the two methods on the same slider agreed well in the region from 20-80 nm, SCATIR is at least comparable to three-wavelength int erferometry, and potentially superior in that (i) signal intensity increase s as the fly height decreases, (ii) calibration and measurement occur in on e location, and (iii) the sensitivity can be optimized for a desired range of fly height.