R. Dufresne et al., Treatment of clean condensate using catalytically enhanced oxidation - Theprocess enables the re-use of clean condensates, PULP PAPER, 102(2), 2001, pp. 31-34
Laboratory testing of catalytic oxidation of evaporator clean condensate is
described. The catalyst system (nickel catalyst, sodium hypochlorite, 10-m
inute contact time provides virtually complete oxidation of the reduced sul
phur species to non-odorous species, with a 10% reduction in COD. In the ab
sence of catalyst, DMS and DMSD remain ain the effluent, and not reduction
in COD is observed. This process is suitable for treating clean condensates
, permitting their re-use within the pulp mill.