A basic study for a robotic transfer aid system based on human motion analysis
Citation
T. Tsuruga et al., A basic study for a robotic transfer aid system based on human motion analysis, ADV ROBOT, 14(7), 2000, pp. 579-595
Categorie Soggetti
AI Robotics and Automatic Control
Journal title
ADVANCED ROBOTICS
SICI code
0169-1864(2000)14:7<579:ABSFAR>2.0.ZU;2-Y
Abstract
A metal hydride (MH) actuator uses the reversible reaction between heat ene
rgy and mechanical energy of a hydrogen-absorbing alloy and moves smoothly
without any noise. Moreover, the actuator is compact, light and has adequat
e compliance. In this paper, some experiments concerning human motion patte
rns were carried out in order to adopt the MH actuator to the transfer aid
system. The results were evaluated from a biomedical engineering viewpoint
in order to obtain the optimal parameters for transferring the disabled fro
m a bed to a wheelchair and vice versa (transfer aid). Sagittal plane kinem
atics, surface electromyographic signals (EMG) obtained from lower limbs, g
round reaction forces and foot pressure distribution were measured using a
three-dimensional motion analyzer. From the experimental results, it was fo
und that the motion of the transfer aid was smooth when the initial angle o
f the ankle was 70 degrees, The best initial angle of the trunk was also fo
und to be about 45 degrees while standing from a bed, However the initial a
ngle of the trunk was best at 60 degrees when a person was in the process o
f sitting down on a wheelchair. Furthermore, a knee pad which supports the
lower limbs requires flexibility in the range of 0.1-0.2 kgf/mm.