The divertor geometry of JT-60U was modified in 1998 to add a pumping slot
near the outer strike point for improved pumping. In the both-side pumping
divertor, the x-point MARFE onset density is similar to 10% higher with pum
ping than without pumping. Radiated power near the x-point is decreased by
pumping, and the divertor pumping is effective in suppression of the x-poin
t MARFE. The effect of outer pumping is investigated in L-mode plasmas. The
onset densities of the x-point MARFE are the same in both diverters. The f
raction of total radiated power over absorbed power at the x-point MARFE on
set is similar to 20% higher in the both-side pumping divertor than in the
inside pumping divertor, but it does not depend on the onset density and on
a distance between the private dome and the outer leg. Carbon penetration
from the divertor region to the main plasma has a weak dependence on the ga
p-out in the both-side pumping divertor. (C) 2001 Elsevier Science B.V. All
rights reserved.