2-DIMENSIONAL IMAGING X-RAY SPECTROMETER FOR PLASMA DIAGNOSTICS
Citation
T. Aota et al., 2-DIMENSIONAL IMAGING X-RAY SPECTROMETER FOR PLASMA DIAGNOSTICS, Fusion engineering and design, 34-5, 1997, pp. 189-191
Categorie Soggetti
Nuclear Sciences & Tecnology
SICI code
0920-3796(1997)34-5:<189:2IXSFP>2.0.ZU;2-Y
Abstract
A two-dimensional imaging soft X-ray monochromator is now under develo
pment. The main components of this spectrometer are a channel plate co
llimator (CPC) and multilayer mirrors, We have applied this monochroma
tor to obtain soft X-ray images of GAMMA10 tandem mirror plasmas. In o
rder to obtain clear images in a low energy X-ray regime, we have util
ized and tested a focusing effect of the CPC. Ray-trace simulations we
re carried out under the same conditions as the experiments. After com
parison of these results, we have confirmed that the focusing effect o
f the CPC is useful in practical use. Monochromatized two-dimensional
soft X-ray images have been successfully taken on the tandem mirror ex
periment. (C) 1997 Elsevier Science S.A.