Simultaneous determination of guanosine and 8-hydroxy-guanosine by differential pulse voltammetry

Authors
Citation
Rn. Goyal et N. Jain, Simultaneous determination of guanosine and 8-hydroxy-guanosine by differential pulse voltammetry, I J CHEM A, 39(11), 2000, pp. 1222-1226
Citations number
24
Categorie Soggetti
Chemistry
Journal title
INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY
ISSN journal
03764710 → ACNP
Volume
39
Issue
11
Year of publication
2000
Pages
1222 - 1226
Database
ISI
SICI code
0376-4710(200011)39:11<1222:SDOGA8>2.0.ZU;2-F
Abstract
Differential pulse voltammetry has been used for the simultaneous determina tion of guanosine and 8-hydroxyguanosine in phosphate buffers. Well-separat ed differential pulse voltammetric peaks for guanosine and 8-hydroxyguanosi ne are observed at pyrolytic graphite electrode. The proposed method is sim ple, rapid and provides a wide determination range of 0.5 muM to 0.1 mM wit h good reproducibility. Interference of ascorbic acid and some guanine rela ted compounds has also been studied and it is found that they do not interf ere at very low concentration level.