The control signals to control the function of devices, inside high voltage
tank of NSC 15 UD accelerator, are carried by means of fibre optic cable.
In one of the operations, the control on some of these devices was lost. Th
e reason for this was the total damage of fibre optic cable. An indigenous
fibre optic connector was developed and a patch was connected in place of d
amaged cable by using these indigenously developed connectors. Apart from t
his a new system, for absolute position lead back of foil stripper, is desi
gned, fabricated and installed in the accelerator at NSC. Foil stripper at
terminal is used to convert negative ion to positive ion and its stripping
efficiency depends upon its health. There are 200 stripper foils in NSC 15
UD pelletron accelerator and it is important to know the condition of each
stripper for the operation of accelerator. This position read back system h
elps to know the status of stripper, in use, accurately. Use of two turbo p
umps modifies gas stripper system used in NSC 15 UD accelerator. During tes
t run it was observed that the operation of turbo pump controller, used for
the operation, was not up to the mark. It broke down twice during the test
run. The controller was then modified for its proper operation.