Effect of teflon piston diameter on hearing result after stapedotomy

Citation
L. Sennaroglu et al., Effect of teflon piston diameter on hearing result after stapedotomy, OTO H N SUR, 124(3), 2001, pp. 279-281
Citations number
12
Categorie Soggetti
Otolaryngology
Journal title
OTOLARYNGOLOGY-HEAD AND NECK SURGERY
ISSN journal
01945998 → ACNP
Volume
124
Issue
3
Year of publication
2001
Pages
279 - 281
Database
ISI
SICI code
0194-5998(200103)124:3<279:EOTPDO>2.0.ZU;2-9
Abstract
This study compares hearing results after stapedotomy by 0.6 mm and 0.8 mm teflon pistons. Retrospective analysis studied 100 patients randomly select ed who underwent stapedotomy for otosclerosis with insertion of 0.8 mm tefl on piston prosthesis and 100 patients with 0.6 mm teflon piston prosthesis. Air-conduction hearing level in both groups were measured before and after the procedure and the gain of the air conduction between the 2 groups at d ifferent frequencies were compared statistically. The group with the 0.8 mm prosthesis had better results that were statistically significant and more pronounced at lower frequencies.