The JT-60 facility is now planning to replace the existing machine with a s
uperconducting machine (JT-60SC) in order to proceed with advanced studies
of steady state plasmas with high performance core conditions close to thos
e of fusion reactor. A maximum plasma current of 4 MA and duration of 100 s
are expected. Existing toroidal and poloidal field coils and vacuum vessel
will be completely replaced. Since the present JT-60 system has been desig
ned for a plasma current duration of 15 s, the coil and power supply system
s need to be reconstructed to ones with a long pulse capability. This paper
describes the new JT-60 machine and the design of the coil power supply sy
stem.