M. Baek et al., Determination of aloesin in rat plasma using a column-switching high-performance liquid chromatographic assay, J CHROMAT B, 754(1), 2001, pp. 121-126
A column-switching high-performance liquid chromatography (HPLC) method for
the determination of aloesin in rat plasma using column-switching and ultr
aviolet (UV) absorbance detection is described. Plasma was directly injecte
d onto the HPLC system consisting of a clean-up column, a concentrating col
umn, and an analytical column, which were connected with a six-port switchi
ng valve. The determination of aloesin was accurate and repeatable, with a
limit of quantitation of 10 ng/ml in plasma. The standard calibration curve
for aloesin was linear (r=0.998) over the concentration range of 10-1000 n
g/ml in rat plasma. The intra- and inter-day assay variabilities of aloesin
ranged from 1.0 to 4.7% and 1.1 to 8.8%, respectively. This highly sensiti
ve and simple method has been successfully applied to a pharmacokinetic stu
dy after oral administration of aloesin to rats. (C) 2001 Elsevier Science
B.V. All rights reserved.