Lg. Chen et al., Theoretical analysis and experimental confirmation of the performance of athermoelectric refrigerator, J NON-EQU T, 26(1), 2001, pp. 85-92
The cooling load and coefficient of performance (COP) expressions for a the
rmoelectric refrigerator, which is composed of multi-elements, are derived
with the consideration of heat transfer irreversibility in the heat exchang
ers between the refrigerator and the reservoirs. An experimental device is
built for the performance investigation of the thermoelectric refrigerator.
The device is used to evaluate the effect of external heat transfer on the
performance of the thermoelectric refrigerator. The theoretical results ar
e compared and confirmed with experimental results.