M. Hirose et al., Development of a 24-anode linear-array fine-mesh PMT with 85% photoelectron detection efficiency and 100 ps TTS at B <= 1 T, NUCL INST A, 460(2-3), 2001, pp. 326-335
By shortening the distance between the photocathode and the first dynode to
I mm and using a finer mesh size of 2500 lines/in. with 4 mum(phi), a 24 a
node linear-array of fine-mesh photomultiplier tube has produced a clear si
ngle-photon peak in its pulse-height distribution under a strong magnetic f
ield of B less than or equal to 1 T, and provided sigma (TTS) = 100 ps of t
ransit time spread (TTS) and 85% of photoelectron detection efficiency. (C)
2001 Elsevier Science B.V. All rights reserved.