Kinetic model for space nonuniform pump in a KrF laser

Citation
Cb. Zhang et al., Kinetic model for space nonuniform pump in a KrF laser, ACT PHY C E, 50(4), 2001, pp. 693-696
Citations number
5
Categorie Soggetti
Physics
Journal title
ACTA PHYSICA SINICA
ISSN journal
10003290 → ACNP
Volume
50
Issue
4
Year of publication
2001
Pages
693 - 696
Database
ISI
SICI code
1000-3290(200104)50:4<693:KMFSNP>2.0.ZU;2-4
Abstract
A three-dementional(3D) kinetic model method for KrF laser is presented. Th e major difference between the method and the previous kinetic method for K rF laser is that the space nonuniform for the electronic pump is considered . The pump rate is considered as a function of 3D space (X, Y, Z) and time (t). Using the 3D model method, 96101702 experiment is simulated. The calcu lated laser energy output and lens energy distribution is in agreement with the experimental results. The problem that the calculated result of 1D mod el is obviously higher than the experimental result is solved.