A new optimizing objective (three-dimensional power distribution control) f
or the load-following problem in nuclear reactor is presented. To realize s
uch an objective. a combination of Harmonic Synthesis Method and Nodal Meth
od has been practiced on the numeric calculation for optimizing problem on
the 200 MW Heating Reactor, in which the control rods serve as the only con
trol variables. In contrast, most of the load-following problems have been
solved under a one-dimensional neutron model. And it seems that such a mode
l is not suitable for the reactor core whose power was controlled only by c
ontrol rods. In this case, the control rod causes a strong absorption of ne
utron in a local area thus makes the radial power distribution play a much
more important role in the load-following process. As the 3-dimensional mod
el is used and the corresponding method is performed. both of the total pow
er level and power distribution are controlled well. For example. the power
peak-factor is lower about 4% than that with one-dimensional method. (C) 2
001 Elsevier Science Ltd. All rights reserved.