H. Masunaga et al., Assessment of gadolinium-enhanced time-resolved three-dimensional MR angiography for evaluating renal artery stenosis, AM J ROENTG, 176(5), 2001, pp. 1213-1219
Citations number
23
Categorie Soggetti
Radiology ,Nuclear Medicine & Imaging","Medical Research Diagnosis & Treatment
OBJECTIVE. The purpose of this study was to assess the image quality of gad
olinium-enhanced time-resolved three-dimensional (3D) MR angiography and to
evaluate its accuracy in revealing renal artery stenosis.
SUBJECTS AND METHODS. Thirty-nine patients underwent MR angiography using a
n ultrafast 3D Fourier transform spoiled gradient-recalled acquisition in t
he steady state (TR/TE range, 2.6/0.7-0.8). Five seconds after administrati
on of 15-20 mL gadodiamide hydrate, four or five consecutive data sets with
imaging times of 7.0-7.6 sec were acquired during a single breath-hold A t
iming examination was not performed. Image quality was assessed using quant
itative analysis (signal-to-noise, contrast-to-noise, and venous-to-arteria
l enhancement ratios) and qualitative analysis (presence of venous overlap,
presence of artifacts, and degree of renal arterial enhancement). MR angio
graphy depiction of the renal artery stenosis was evaluated using conventio
nal angiography as the standard of reference.
RESULTS. On the best arterial phase, average aortic signal-to-noise ratio (
+/- SD) was 74.5 +/- 24.4, aorta-to-inferior vena cava contrast-to-noise ra
tio was 70.8 +/- 23.4, and inferior vena cava-to-aorta venous-to-arterial e
nhancement ratio was 0.03 +/- 0.01. No venous overlap was seen in 35 of 39
patients. Substantial enhancement of renal arteries was seen in all patient
s without any noticeable artifacts. MR angiography correctly depicted the d
egree of stenosis in 44 of 47 normal arteries, 13 of 16 mildly stenotic art
eries, five of five moderately stenotic arteries, three of four severely st
enotic arteries, and one of one occluded artery. Sensitivity and specificit
y for revealing greater than 50% stenosis was 100%.
CONCLUSION. Time-resolved 3D MR angiography can provide high-quality arteri
ograms. Its performance in revealing renal artery stenosis is comparable wi
th that of conventional angiography.