Biaxial fatigue behaviour of a multidirectional filament-wound glass-fiber/epoxy pipe

Citation
F. Ellyin et M. Martens, Biaxial fatigue behaviour of a multidirectional filament-wound glass-fiber/epoxy pipe, COMP SCI T, 61(4), 2001, pp. 491-502
Citations number
20
Categorie Soggetti
Material Science & Engineering
Journal title
COMPOSITES SCIENCE AND TECHNOLOGY
ISSN journal
02663538 → ACNP
Volume
61
Issue
4
Year of publication
2001
Pages
491 - 502
Database
ISI
SICI code
0266-3538(2001)61:4<491:BFBOAM>2.0.ZU;2-P
Abstract
This paper presents the results of an experimental investigation into the b iaxial fatigue behaviour of a filament-wound multidirectional glass-fiber/e poxy pipe. Tests were conducted to observe the leakage (functional) failure of the composite pipe subjected to various hoop to axial loadings. The sti ffness change in the axial and hoop directions, fatigue life curves, biaxia l fatigue envelopes at various lives, and failure mechanisms are discussed. It is noted that optimum fiber placement in principal directions may lead to a weak behaviour for an intermediate loading combination. It is also fou nd that monotonic test data are not a good indicator of the fatigue behavio ur. Furthermore, imperfections in the manufacturing process lead to early d amage initiation under cyclic loading, and result in shorter Fatigue lives to leakage. (C) 2001 Elsevier Science Ltd. All rights reserved.