For the determination of superconducting properties of HTS wires and tapes
an exact analysis of the cross section of the silver sheath and the filamen
ts is essential. The normal procedure for this analysis is to perform image
analysis on optical microscopic or SEM images of the conductor cross secti
on. These methods are very time consuming and reflect only a snapshot of th
e average cross section of the wires / tapes, because the detection is only
local. To overcome these difficulties an easy method has been developed to
determine cross section in a chemical way via titration. The obtained data
reflect an average silver and filament cross section over variable conduct
or lengths. In addition the porosity of the filaments can easily be calcula
ted.