A pair of Superconducting Septum Magnets are required to permit Hypernuclea
r Physics Experiments at JLAB's Hall A at angles to the incident beam as sm
all as 6 degrees. A Cold Iron Superconducting " C " magnet design has been
selected. This magnet has a central field of 4.23 Tesla at a current densit
y of 25,000 Amp/cm2, the stored energy is 0.22 Megajoules and the inductanc
e is 1.0 Henries. The magnet has an effective field length of 0.67 meters,
an average gap of 0.25 meters and an average pole width of 0.15 meters. The
magnet is currently being fabricated by BWXT Inc. under contract to INFN.