Calorimetric measurements of losses in HTS cables

Citation
C. Traeholt et al., Calorimetric measurements of losses in HTS cables, IEEE APPL S, 11(1), 2001, pp. 1777-1780
Citations number
9
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Journal title
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
ISSN journal
10518223 → ACNP
Volume
11
Issue
1
Year of publication
2001
Part
2
Pages
1777 - 1780
Database
ISI
SICI code
1051-8223(200103)11:1<1777:CMOLIH>2.0.ZU;2-Q
Abstract
A calorimetric test rig is used to investigate various loss components in a 10 m long superconducting cable model. A calorimetric technique, based on thermocouple measurements, Is used to me asure the losses of the 10 m long superconducting cable model. The current dependent losses;Ire also measured electrically and compared with the losse s obtained with the calorimetric method. The results obtained by the two me thods are consistent. Based on an I-2 (current) fitting procedure, the loss,:caused by the eddy c urrent generated in the stainless steel cryostat housing, and the hysteresi s loss generated in the conductor can be separated. From this result, it ap pears that the two contributions are roughly equal in size.