The helical coils for the Large Helical Device are the world's largest pool
-cooled superconducting coils in operation, These were expected to be cryos
table up to 13.0 kA at 4.4 K on a basis of the measured recovery currents i
n all the short samples. However, a normal-zone was induced at higher than
11 kA repeatedly, It propagated to the finite length and recovered within s
everal seconds except at 11.45 kA. Because of slow current diffusion into a
pure aluminum stabilizer, a normal zone can propagate dynamically below th
e cold end recovery current. The excitation tests have been carried out, an
d average 11.65 kA has been achieved by grading the current in the three bl
ocks of the helical coil. The disturbance during excitations and the cryoge
nic stability of the coil are presented.