In case of manufacturing the applied superconducting machines using High-Tc
superconductor (HTS) such as SMES, MAGLEV, and superconducting generator,
superconducting joint is very important because they need very long tapes.
For this reason, the investigation of AC Loss of jointed tapes should be co
nsidered as well as that of the AC Loss of jointless tapes, and so we inves
tigated the tendency of Ae Loss with superconducting joint, and compared th
e AC Loss of jointed tapes with that of jointless tapes. Zn this paper, the
;AC Loss in BSCCO-2223 silver (Ag) sheathed tapes was measured by using fou
r-probe transport technique at 77 K.
Firstly, it was shown that the experimental measurement of AC loss in the t
apes agree well with the calculated values provided by Norris equation, Mor
eover, it was shown that the AC loss depends on amplitude of transport curr
ent. Finally? it was shown that the AC Loss depends on joint resistance and
Andes n.