Dynamic range of frequency-selective response of high-T-c Josephson detector to millimeter-wave radiation

Citation
V. Shirotov et al., Dynamic range of frequency-selective response of high-T-c Josephson detector to millimeter-wave radiation, IEEE APPL S, 11(1), 2001, pp. 955-957
Citations number
5
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Journal title
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
ISSN journal
10518223 → ACNP
Volume
11
Issue
1
Year of publication
2001
Part
1
Pages
955 - 957
Database
ISI
SICI code
1051-8223(200103)11:1<955:DROFRO>2.0.ZU;2-7
Abstract
We have studied a voltage dependence of the response DeltaI(V) of high-T-c Josephson detector to millimeter-wave radiation as a function of power of i ncident radiation. YBa2Cu3O7-x grain-boundary junctions with the resistance s R-x = 0.5-1.5 Ohm and the Wt-product In the range 0.16-0.25 mV at 80 It h ave been fabricated for this study. Gunn oscillator with the frequency f= 8 6 GHz and a set of calibrated attenuators with total attenuation of 80 dB h ave been used for the measurements. The dynamic range, i.e. the range of po wer of electromagnetic radiation at which the response of the detector is d irectly proportional to radiation power, was found to be around 40 dB above the noise-equivalent power for frequency-selective response V voltages V n ear hf/2e and > 45 dB for the broadband response at low voltages.