Experimental investigation on ammonia spray evaporator with triangular-pitch plain-tube bundle, Part II: evaporator performance

Citation
X. Zeng et al., Experimental investigation on ammonia spray evaporator with triangular-pitch plain-tube bundle, Part II: evaporator performance, INT J HEAT, 44(11), 2001, pp. 2081-2092
Citations number
17
Categorie Soggetti
Mechanical Engineering
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
ISSN journal
00179310 → ACNP
Volume
44
Issue
11
Year of publication
2001
Pages
2081 - 2092
Database
ISI
SICI code
0017-9310(200106)44:11<2081:EIOASE>2.0.ZU;2-1
Abstract
Spray evaporation of ammonia was tested using spray nozzles distributing li quid ammonia downward onto a horizontal, 3-2-3 triangular-pitch, 1.25 pitch ratio, plain-tube bundle composed of stainless-steel tubes of 19 mm (0.75 in.) diameter. The saturation temperature test range was from -23 degreesC to 10 degreesC, and the heat flux range from 3.2 to 35 kW/m(2). The effects of heat flux, saturation temperature, spray flow rate, nozzle height, and nozzle type (standard-angle or wide-angle) were investigated. The spray eva poration heat transfer performance was compared with that of pool boiling, as well as spray evaporation on square-pitch tube bundle and single tube. ( C) 2001 Elsevier Science Ltd. All rights reserved.