Experimental verification and optimisation of a detailed dynamic high performance liquid chromatography column model

Citation
Hk. Teoh et al., Experimental verification and optimisation of a detailed dynamic high performance liquid chromatography column model, COMPUT CH E, 25(4-6), 2001, pp. 893-903
Citations number
13
Categorie Soggetti
Chemical Engineering
Journal title
COMPUTERS & CHEMICAL ENGINEERING
ISSN journal
00981354 → ACNP
Volume
25
Issue
4-6
Year of publication
2001
Pages
893 - 903
Database
ISI
SICI code
0098-1354(20010501)25:4-6<893:EVAOOA>2.0.ZU;2-I
Abstract
Detailed mathematical models of chromatographic separation processes is of crucial importance due to the increased application of this separation tech nique in the downstream processes of the biotechnological, pharmaceutical a nd fine chemical industries. In this paper, a detailed dynamic model of a h igh performance liquid chromatographic unit was experimentally verified and used as the basis for the optimisation of a preparative chromatographic se paration using closed-loop recycling operation. Results confirmed that tile effective column length could be increased by as much as 200% by recycling the feed sample back to the column for further purification with a concomi tant improvement in purity and yield of the process. Data is presented to s how the limitations of the method and the influence of key variables on col umn performance. Q 2001 Elsevier Science Ltd. All rights reserved.