Transient response in a dc-dc converter employing load-current feedforwardcontrol

Citation
S. Kanemaru et al., Transient response in a dc-dc converter employing load-current feedforwardcontrol, ELEC C JP 1, 84(8), 2001, pp. 14-22
Citations number
6
Categorie Soggetti
Information Tecnology & Communication Systems
Journal title
ELECTRONICS AND COMMUNICATIONS IN JAPAN PART I-COMMUNICATIONS
ISSN journal
87566621 → ACNP
Volume
84
Issue
8
Year of publication
2001
Pages
14 - 22
Database
ISI
SICI code
8756-6621(2001)84:8<14:TRIADC>2.0.ZU;2-D
Abstract
Load-current feedforward control applied to a voltage-controlled buck-type de-de converter is proposed in order to reduce output voltage deviation. Th e design conditions that optimize the transfer characteristics of the curre nt transformer for load current sensing are identified by introducing the i ntegral of the square of the output voltage deviation as a performance inde x. An effective region of feedforward control limited by the saturation cha racteristics of the PWM is considered quantitatively. The usefulness of the proposed method and the stability problem when the bulk capacitor is added to the load are examined. (C) 2001 Scripta Technica