In-situ calibration of boiler instrumentation using analytic redundancy

Citation
Gh. Wei et al., In-situ calibration of boiler instrumentation using analytic redundancy, INT J ENERG, 25(5), 2001, pp. 375-387
Citations number
12
Categorie Soggetti
Environmental Engineering & Energy
Journal title
INTERNATIONAL JOURNAL OF ENERGY RESEARCH
ISSN journal
0363907X → ACNP
Volume
25
Issue
5
Year of publication
2001
Pages
375 - 387
Database
ISI
SICI code
0363-907X(200104)25:5<375:ICOBIU>2.0.ZU;2-C
Abstract
This paper presents a broadly useful diagnostic methodology, which engineer s and plant managers can use to detect system faults and find the in-situ o perating characteristics of boilers when some metered data are either missi ng or obviously erroneous. The methodology is able to analyse conflicting m easurements and utilize analytic redundancy (AR) to deduce the measurement or measurements that are substantially in error without shutting down the p lant and recalibrating all instrumentation. The application of the AR techn ique in evaluating boiler performance is presented through a case study. Co pyright (C) 2001 John Wiley & Sons, Ltd.