A Davis tube (a matrix-free, flow-through magnetic separator used mainly in
mineral processing) has been tested for separation of magnetic affinity bi
opolymer adsorbents from larger volumes of suspensions. Both magnetic chito
san and magnetic cross-linked erythrocytes could be efficiently separated f
rom litre volumes of suspensions. Up to 90% adsorbent recovery was achieved
under optimised separation conditions.