A new rapid method for quantification of PCBs in transformer oil
Citation
M. Takada et al., A new rapid method for quantification of PCBs in transformer oil, CHEMOSPHERE, 43(4-7), 2001, pp. 455-459
Categorie Soggetti
Environment/Ecology
Journal title
CHEMOSPHERE
SICI code
0045-6535(200105/06)43:4-7<455:ANRMFQ>2.0.ZU;2-3
Abstract
In order to improve the efficiency and cost-effectiveness of the PCB analys
is, the DMSO partition and SPE extraction were applied to clean up the PCB-
contaminated transformer oils and PCB level was determined by means of the
quadrupole GC/MS. The analysis data obtained from this method were compared
statistically to that from the standard method. (C) 2001 Elsevier Science
Ltd. All rights reserved.