Determination of heparin on intraocular lens surfaces by ion chromatography

Citation
B. Ander et al., Determination of heparin on intraocular lens surfaces by ion chromatography, J CHROMAT A, 917(1-2), 2001, pp. 105-110
Citations number
7
Categorie Soggetti
Chemistry & Analysis","Spectroscopy /Instrumentation/Analytical Sciences
Journal title
Volume
917
Issue
1-2
Year of publication
2001
Pages
105 - 110
Database
ISI
SICI code
Abstract
A sensitive and selective method has been developed for the determination o f heparin on heparin coated PMMA, poly(methyl methacrylate), intraocular le nses. Heparin was hydrolysed to glucosamine and glucuronic acid, and the co ntent of glucosamine was determined using ion chromatography with pulsed am perometric detection. In order to verify that a complete hydrolysis was obt ained for the heparin on the coated intraocular lenses, electron spectrosco py for chemical analysis (ESCA) was used for analysing traces of sulphur on the lens surfaces. The sensitivity of the method allows quantitative deter mination of 150 ng of heparin on one individual lens. The new method was co mpared to a standard spectrophotometric method, measuring the colour intens ity of a heparin toluidine blue complex. Correlation between the methods wa s shown for samples prepared from PMMA lenses coated with different amounts of heparin. (C) 2001 Elsevier Science B.V. All rights reserved.