An experimental investigation was conducted in order to verify the theoreti
cal model described in Part 1 as well as to obtain experimental insight and
to generate a database for the post-buckling behavior of composite I-secti
ons. The experiments were performed using a combination of the shadow moire
technique, strain gages, LVDTs (linear variable differential transformer),
and dial gages. A total of twenty carbon-fiber/epoxy I-section columns wer
e manufactured and tested with seven specimens from woven fabric and thirte
en from unidirectional (UD) tape. The initial buckling load, lateral deflec
tion of the web and flange as well as the crippling load were measured. The
experimental results were compared with those of the theoretical model des
cribed in Part 1. A good agreement was observed.