MEASUREMENT AND REDUCTION OF EMI RADIATED BY A PWM INVERTER-FED AC MOTOR DRIVE SYSTEM

Citation
S. Ogasawara et al., MEASUREMENT AND REDUCTION OF EMI RADIATED BY A PWM INVERTER-FED AC MOTOR DRIVE SYSTEM, IEEE transactions on industry applications, 33(4), 1997, pp. 1019-1026
Citations number
11
Categorie Soggetti
Engineering,"Engineering, Eletrical & Electronic
ISSN journal
00939994
Volume
33
Issue
4
Year of publication
1997
Pages
1019 - 1026
Database
ISI
SICI code
0093-9994(1997)33:4<1019:MAROER>2.0.ZU;2-F
Abstract
This paper presents theoretical and experimental relationships between radiated electromagnetic noises and common-mode and normal-mode curre nts, paying attention to an induction motor drive system fed by a volt age-source pulsewidth modulation (PWM) inverter. A method of reducing both currents is proposed, based on an equivalent model, taking into a ccount parasitic stray capacitors inside an induction motor. Electroma gnetic interference (EMI) radiated by a 3.7-kW induction motor drive s ystem is actually measured, complying with the VDE 0871 Class A [3 m]. Experimental results verify that the combination of the already propo sed common-mode transformer (CMT) and the normal-mode filters (NMF's) being proposed in this paper is a practically viable and effective way to reduce EMI resulting from both common-mode and normal-mode current s.