Correction-factor analysis of solvent extraction in multipass membrane modules with recycle

Authors
Citation
Hm. Yeh et Cs. Chen, Correction-factor analysis of solvent extraction in multipass membrane modules with recycle, J MEMBR SCI, 187(1-2), 2001, pp. 103-108
Citations number
13
Categorie Soggetti
Chemistry,"Chemical Engineering
Journal title
JOURNAL OF MEMBRANE SCIENCE
ISSN journal
03767388 → ACNP
Volume
187
Issue
1-2
Year of publication
2001
Pages
103 - 108
Database
ISI
SICI code
0376-7388(20010615)187:1-2<103:CAOSEI>2.0.ZU;2-A
Abstract
The analysis of solvent extraction in multipass membrane modules with recyc le has been carried out by the correction-factor method, analogous to heat transfer in multipass heat exchangers. The theoretical predictions confirm pretty well with the experimental results. It is concluded that when the in crease in mass-transfer coefficient by applying the recycle effect can comp ensate for the decrease in the driving force of mass transfer, the membrane extractors with recycle operation are recommended to be employed. (C) 2001 Elsevier Science B.V. All rights reserved.