D. Belic et al., The new photoactivation facility at the 4.3 MV Stuttgart DYNAMITRON: setup, performance, and first applications, NUCL INST A, 463(1-2), 2001, pp. 26-41
At the Stuttgart 4.3 MV DYNAMITRON accelerator a new bremsstrahlung irradia
tion facility was installed for photoactivation experiments to complement t
he well-established arrangement for systematic photon-scattering studies ta
king advantage of the high photon fluxes achievable at this high-current ac
celerator. The population or depopulation of isomeric states in low-energy
photon-induced reactions (E-gamma = 0.5-4.0 MeV) can be studied with sensit
ivities far beyond previous limits. The setup of this facility, its perform
ance, and the absolute calibrations are described in detail. First exemplar
y results for a test case, the reaction In-115(gamma, gamma')In-115m, are p
resented and analyzed in combination with data from tow-energy photon-scatt
ering experiments (In-115(gamma, gamma')In-115). The quality of the results
demonstrates the powerful capability of this new installation (C) 2001 Els
evier Science B.V. All rights reserved.