C. Rose-sallin et al., Comparison of microbiological and HPLC-fluorescence detection methods for determination of niacin in fortified food products, FOOD CHEM, 73(4), 2001, pp. 473-480
A comparison has been made between results obtained by a recently published
HPLC method, involving post-column reaction and fluorescence detection. wi
th a microbiological assay using Lactobacillus plantarum. The HPLC method i
ncludes a modified acid hydrolysis extraction step (0.1 M HCl) and yields n
iacin values from fortified foods somewhat lower than by the microbiologica
l assay. The most significant differences were observed for the cereal-base
d products. These differences arise principally from the lack of specificit
y of L. plantarum and from the stronger acid hydrolysis extraction conditio
ns (1 M HCl) of the microbiological assay, which probably releases a part o
f the non-bioavailable niacin. Moreover by HPLC, excellent recoveries of ad
ded nicotinic acid and nicotinamide (95-100%) were obtained and better prec
ision (RSDr = 0.3-0.8%) was observed than from the micobiological assay. (C
) 2001 Elsevier Science Ltd. All rights reserved.