A rare case of sciatic nerve palsy in an uncemented modular hip arthroplast
y is described. We believe that a delay in recognizing liner dissociation c
ausing granuloma was responsible for the nerve palsy. Delay in diagnosis ca
n be avoided by a careful inspection of prereduction and postreduction radi
ographs.