A new equation of secondary current distribution of the Hull cell is derive
d which can explain the influence of some electrochemical kinetics and mass
transport on the quality of electrodeposit, and can give some instructions
for the electroplating using indirect current and for the study of seconda
ry current distribution in a modified Hull cell. The results from the theor
etical equation and experimental measurement are compared with that of othe
r experimental formula. It is shown that the result from the theoretical eq
uation is more suitable to the actual conditions than that from the empiric
al formula. (C) 2001 The Electrochemical Society [DOI: 10.1149/1.1277594] A
ll rights reserved.