Tj. Carroll et al., Carotid bifurcation: Evaluation of time-resolved three-dimensional contrast-enhanced MR angiography, RADIOLOGY, 220(2), 2001, pp. 525-532
Citations number
24
Categorie Soggetti
Radiology ,Nuclear Medicine & Imaging","Medical Research Diagnosis & Treatment
A magnetic resonance (MR) angiographic protocol was evaluated in the caroti
d bifurcation with use of a pulse sequence for time-resolved three-dimensio
nal imaging of contrast material kinetics. The enhancement ratio, a quantit
ative measure of contrast enhancement, indicated that all studies included
an image obtained near the peak of the intraarterial concentration of contr
ast agent (enhancement ratio, 90% +/- 9 [standard deviation]). Studies acqu
ired at a higher frame rate (4.1-4.9 seconds) exhibited less venous enhance
ment (enhancement ratio, 25% +/- 16) than studies acquired with slower (6.0
-9.6-second) frame rates (enhancement ratio, 46% +/- 25).