A. De Luca et al., Base isolation for retrofitting historic buildings: Evaluation of seismic performance through experimental investigation, EARTH EN ST, 30(8), 2001, pp. 1125-1145
An experimental test program on a full-scale model representing a sub-assem
blage of the cloister facade of the Sao Vicente de Fora monastery, retrofit
ted through base isolation, has been recently carried out at the European L
aboratory for Structural Assessment of the Joint Research Centre of the Eur
opean Commission. In this paper an overview of the laboratory model and the
experimental results is provided. In particular, firstly the test model is
described, including the geometry and mechanical properties of the masonry
specimen and the design of the isolation devices; then the testing method
and the substructuring of the isolation system are described and the seismi
c inputs adopted for the pseudo-dynamic tests are defined. Finally, the exp
erimental results are discussed and compared to the analogous results obtai
ned on the 'as is', fixed-base sub-assemblage model. The implications of th
e test outcomes are emphasized and developments of this research line are p
resented. Copyright (C) 2001 John Wiley & Sons, Ltd.