Application of a Raman distributed temperature sensor to the experimental fast reactor JOYO with correction techniques

Citation
A. Kimura et al., Application of a Raman distributed temperature sensor to the experimental fast reactor JOYO with correction techniques, MEAS SCI T, 12(7), 2001, pp. 966-973
Citations number
13
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
MEASUREMENT SCIENCE & TECHNOLOGY
ISSN journal
09570233 → ACNP
Volume
12
Issue
7
Year of publication
2001
Pages
966 - 973
Database
ISI
SICI code
0957-0233(200107)12:7<966:AOARDT>2.0.ZU;2-O
Abstract
In order to apply a Raman distributed temperature sensor (RDTS) to the moni toring of nuclear facilities, some correction techniques for radiation-indu ced errors were developed and investigated. One is a simple correction tech nique with two thermocouples, when uniform radiation-induced loss distribut ion can be assumed. The other is a special technique with a loop-type arran gement. In this technique, even when the loss distribution is not uniform, radiation-induced errors can be cancelled. To demonstrate these techniques, RDTS has been installed at the experimenta l fast reactor JOYO. During continuous measurements with a total dose of mo re than 7.7 x 10(3) C kg(-1) (3.0 x 10(7) R), the radiation-induced error s howed a tendency to saturate and the feasibility of the correction techniqu es was demonstrated. These results show that RDTS could be useful as a temp erature distribution monitor in nuclear plants.