A CRYOCONDENSATION PUMP FOR A HIGH-DENSITY ATOMIC-HYDROGEN JET TARGET

Citation
Jd. Arnold et al., A CRYOCONDENSATION PUMP FOR A HIGH-DENSITY ATOMIC-HYDROGEN JET TARGET, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 391(3), 1997, pp. 398-404
Citations number
11
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
391
Issue
3
Year of publication
1997
Pages
398 - 404
Database
ISI
SICI code
0168-9002(1997)391:3<398:ACPFAH>2.0.ZU;2-Q
Abstract
A large cryocondensation pump for an intense atomic hydrogen beam was designed, fabricated, and tested; its compact design allowed a total c opper cryopanel area of about 15 m(2). The cryopanels operated at abou t 2.6 K. For an atomic hydrogen beam of up to 3.2 x 10(18) atoms s(-1) , the measured pumping speed was about 1.2 x 10(7) 1s(-1), which is 4. 2 x 10(26) atoms Torr(-1) s(-1).