I. Bassiotis et al., Effects of experimental parameters in quantitative analysis of steel alloyby laser-induced breakdown spectroscopy, SPECT ACT B, 56(6), 2001, pp. 671-683
Calibration curves for the elements Cr, Ni and Mn in commercial steel alloy
samples were obtained employing the Internal Standardization method in atm
ospheric air pressure. A number of experimental parameters have been optimi
zed in order that the produced calibration curves showed good linearity ove
r a broad range of concentrations covered by the alloy elements. Emphasis w
as given to the development of the method for field analysis and for the on
-line control of production processes. (C) 2001 Elsevier Science B.V. All r
ights reserved.