This paper describes the seismic behaviour of chevron steel braced frames f
or 2-, 4-, 8-, and 12-storey steel building structures. Two different desig
n approaches were considered: one that corresponds to current CSA-S16.1 sei
smic provisions for braced frames with nominal ductility with an R factor o
f 2.0, and one in which the beams are sized to develop a fraction of the yi
eld tension capacity of the bracing members. In this second approach, an R
factor of 3.0 was used for determining the seismic loads and chevron bracin
g with stronger beams capable of developing 100%, 80%, and 60% of the brace
yield load were examined. The results show that current S16.1 provisions f
or chevron braced frames may lead to systems that are prone to dynamic inst
ability for 4-storey and taller structures. Chevron bracing with stronger b
eams exhibits a more stable inelastic response and can be used for structur
es up to 8 storeys in height. For 2- and 4-storey buildings, chevron braced
frames with beams designed to develop only 60% of the brace yield resistan
ce can be used. The analyses also show that the force demand in brace conne
ctions, beams, and columns as determined from capacity design provisions ag
ree well with that anticipated under strong ground motions.