The measurement of thermal conductivity of alcohols from 0 to 80 degrees Cby the transient technique

Citation
Ml. Yang et al., The measurement of thermal conductivity of alcohols from 0 to 80 degrees Cby the transient technique, HEAT MASS T, 37(4-5), 2001, pp. 507-509
Citations number
7
Categorie Soggetti
Mechanical Engineering
Journal title
HEAT AND MASS TRANSFER
ISSN journal
09477411 → ACNP
Volume
37
Issue
4-5
Year of publication
2001
Pages
507 - 509
Database
ISI
SICI code
0947-7411(200107)37:4-5<507:TMOTCO>2.0.ZU;2-4
Abstract
The thermal conductivities of n- octanol, n- nonanol and n-decanol were mea sured in the temperature range from 0 to 80 degreesC, by means of a compute r-controlled transient calorimeter. The relations of the thermal conductivi ties of the three alcohols to temperature were derived as lambda (mW/mK) = A - Bt, where A are 165.8, 167.8 and 169.4 mW/mK and B are 0.273, 0.287 and 0.293 mW/mK(2) for n-octanol, n-nonanol and n-decanol, respectively. The r esults obtained in this work is much better than the values reported in lit erature due to the calorimeter being considered to be able to eliminate the effects of convection and radiation.