A comparison of hot-gas by-pass and suction modulation method for partial load control in refrigerated shipping containers

Citation
Cp. Tso et al., A comparison of hot-gas by-pass and suction modulation method for partial load control in refrigerated shipping containers, INT J REFR, 24(6), 2001, pp. 544-553
Citations number
4
Categorie Soggetti
Mechanical Engineering
Journal title
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID
ISSN journal
01407007 → ACNP
Volume
24
Issue
6
Year of publication
2001
Pages
544 - 553
Database
ISI
SICI code
0140-7007(200109)24:6<544:ACOHBA>2.0.ZU;2-L
Abstract
Simulation studies using a mathematical model are made to compare the perfo rmance of the hot-gas by-pass control and the suction modulation control in refrigerated shipping containers. Key factors such as compressor power dra w, coefficient of performance and the sensible heat factor of evaporator co il against variations in container load, sct-point and ambient temperatures are examined. Results show that the suction modulation control strategy is the more energy efficient of the two. The evaporator performance is found to be largely unaffected by either strategy. The analysis indicates the pos sibility of controlling relative humidity in the cargo space by variation o f the superheat level. (C) 2001 Elsevier Science Ltd and IIR. All rights re served.