Cp. Tso et al., A comparison of hot-gas by-pass and suction modulation method for partial load control in refrigerated shipping containers, INT J REFR, 24(6), 2001, pp. 544-553
Citations number
4
Categorie Soggetti
Mechanical Engineering
Journal title
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID
Simulation studies using a mathematical model are made to compare the perfo
rmance of the hot-gas by-pass control and the suction modulation control in
refrigerated shipping containers. Key factors such as compressor power dra
w, coefficient of performance and the sensible heat factor of evaporator co
il against variations in container load, sct-point and ambient temperatures
are examined. Results show that the suction modulation control strategy is
the more energy efficient of the two. The evaporator performance is found
to be largely unaffected by either strategy. The analysis indicates the pos
sibility of controlling relative humidity in the cargo space by variation o
f the superheat level. (C) 2001 Elsevier Science Ltd and IIR. All rights re
served.