Determination of fluvastatin and its five metabolites in human plasma using simple gradient reversed-phase high-performance liquid chromatography with ultraviolet detection
A. Nakashima et al., Determination of fluvastatin and its five metabolites in human plasma using simple gradient reversed-phase high-performance liquid chromatography with ultraviolet detection, J CHROMAT B, 760(1), 2001, pp. 17-25
A simple gradient reversed-phase high-performance chromatographic method wi
th ultraviolet detection for the determination of fluvastatin (FV) and its
five metabolites, (M-2, M-3, M-4, M-5 and M-7) in human plasma was develope
d and validated. The limit of quantification of FV and its five metabolites
in human plasma was 10 ng ml(-1). The assay had satisfactory selectivity,
recovery, linearity and precision accuracy. Stability studies showed that F
V and its five metabolites were stable in plasma up to at least 1 month of
storage at -30 degreesC. (C) 2001 Elsevier Science B.V. All rights reserved
.