Total hip arthroplasty imparts significant physical forces on the patient a
t the time of surgery. We report a case of an injury to the superior mesent
eric vein that is thought to have occurred at the time of impaction of the
acetabular component of a total hip arthroplasty. This complication has bee
n reported previously only from high-energy nonpenetrating trauma, such as
motor vehicle accidents.