A limited sampling strategy for cyclosporine area under the curve monitoring in lung transplant recipients

Citation
Rj. Dumont et al., A limited sampling strategy for cyclosporine area under the curve monitoring in lung transplant recipients, J HEART LUN, 20(8), 2001, pp. 897-900
Citations number
23
Categorie Soggetti
Cardiovascular & Respiratory Systems
Journal title
JOURNAL OF HEART AND LUNG TRANSPLANTATION
ISSN journal
10532498 → ACNP
Volume
20
Issue
8
Year of publication
2001
Pages
897 - 900
Database
ISI
SICI code
1053-2498(200108)20:8<897:ALSSFC>2.0.ZU;2-H
Abstract
We developed a limited sampling strategy (LSS) for predicting cyclosporine (Neoral) area under the curve from concentration-time data obtained specifi cally from lung transplant recipients. The optimal and most clinically conv enient LSS for lung transplant recipients, based on patient wait time, numb er of blood samples required, percent prediction error, and assessment of p redictive performance is one that requires 2 blood samples collected at 1 a nd 3 hours post-dose: AUC = 1.75 x C-1 + 4.91 x C-3 + 185.62.