Hm. Yeh, SBM 38 > Effects of inclined angle and plate spacing on the enrichment of heavy water in batch-type flat-plate thermal diffusion columns, SEP PURIF T, 24(1-2), 2001, pp. 147-153
Based on the operating and fixed charge kept unchanged, considerable improv
ement in the performance for enrichment of heavy water in a batch-type flat
-plate thermal diffusion column is obtainable if operation is carried out b
y increasing the inclined angle and/or by decreasing the plate spacing. How
ever, decreasing the plate spacing will lead to decreasing the amount of so
lution to be treated in the column, while increasing the inclined angle wil
l enlarge the operating time for reaching the steady state. (C) 2001 Elsevi
er Science B.V. All rights reserved.